Delta X 2 Plus — G-code reference

Commands, parameters, and practical examples for Delta X 2 Plus.

On this page G00, G01 - Linear Move G02, G03 - Arc or Circle Move G04 - Dwell/Delay G05 - Bézier cubic spline G06 - Theta angle control G28 - Homing G90 - Absolute Movement Mode G91 - Relative Movement Mode G93 - Get Current Position M03 - Vacuum On / Gripper Close M04 - Turn on digital output pins M05 - Vacuum Off / Gripper Open M06 - Turn off digital output pins M07 - Read Input Signals M08 - Read Input Signals Automatically M09 - Disable Automatic Reading Analog Input Signal M50 - Enable RJ45 M51 - Set Ethernet Port M52 - Set MAC Device M53 - Set Ethernet IP M54 - Set Ethernet DNS M55 - Set Ethernet Gateway M56 - Set Ethernet Subnet M57 - Get Robot IP M84 - Disable Steppers M203 - Set Feedrate M204 - Set Acceleration M205 - Set Begin/End Velocity M206 - Set Axis Offset M207 - Set Z Safe M210 - Set Theta Movement Parameter M360 - Select End Effector M361 - Set minimum moving distance M500 - Save Settings M501 - Restore Settings M502 - Reset Settings Contact Us
Command index 36 commands

Gcodes for Delta X 2

G00, G01 - Linear Move

Descriptions

The G0 and G1 commands add a LINEAR MOVE to the queue to be performed after all previous moves are completed.

Set F (feed rate), A (acceleration), J (jerk), S (start velocity), and E (end velocity) once. Subsequent movement commands use these settings until changed; motion parameters omitted from a command keep their current settings.

Usage

G00 [F<rate>] [X<pos>] [Y<pos>] [Z<pos>] [W<angle>] [U<angle>]
G01 [F<rate>] [A<rate>] [J<rate>] [S<rate>] [E<rate>] [X<pos>] [Y<pos>] [Z<pos>] [W<angle>] [U<angle>]

Parameters

ParameterDescription
F[rate](mm/s) The maximum movement rate of the move between the start and endpoint. The feedrate set here applies to subsequent moves that omit this parameter.
A[rate](mm/s^2) The maximum acceleration of the movement.
J[rate](mm/s^3) The jerk of the movement.
S[rate](mm/s) The start velocity of the movement.
E[rate](mm/s) The end velocity of the movement.
X[pos](mm) A coordinate on the X-axis.
Y[pos](mm) A coordinate on the Y-axis.
Z[pos](mm) A coordinate on the Z-axis.
W[angle](mm) A coordinate on the 4-axis.
U[angle](mm) A coordinate on the 5-axis.

Example

G01 X12                         ;move to 12mm on the X-axis
G01 F200                        ;set the feedrate to 200 mm/s
G01 X90.6 Y13.8                 ;move to 90.6mm on the X-axis and 13.8mm on the Y-axis     
G01 X0 Y0 Z-350                 
G01 W90                         ;rotate to 90 degree on the 4-axis
G01 X100 Y50 Z-400 W90 U45 F200 ;X=100 mm, Y=50 mm, Z=-400 mm, W=90°, U=45°, F=200 mm/s

G02, G03 - Arc or Circle Move

Descriptions

G2 adds a clockwise arc move to the planner; G3 adds a counter-clockwise arc. An arc move starts at the current position and ends at the given XYZ, pivoting around a center-point offset given by I and J.

Usage

G2 [F<rate>] [I<offset>] [J<offset>] [X<pos>] [Y<pos>] [W<angle>] [U<angle>]
G3 [F<rate>] [I<offset>] [J<offset>] [X<pos>] [Y<pos>] [W<angle>] [U<angle>]

Parameters

ParameterDescription
F[rate](mm/s) The maximum movement rate of the move between the start and endpoint. The feedrate set here applies to subsequent moves that omit this parameter.
I[offset](mm) An offset from the current X position to use as the arc center.
J[offset](mm) An offset from the current Y position to use as the arc center.
X[pos](mm) A coordinate on the X-axis.
Y[pos](mm) A coordinate on the Y-axis.
W[angle](mm) A coordinate on the 4-axis.
U[angle](mm) A coordinate on the 5-axis.

Example

G28
G01 Z-350
G01 X50
G02 X-50 Y0 I-50 J0
G03 X50 Y0 I50 J0

G04 - Dwell/Delay

Descriptions

Dwell pauses the command queue and waits for a period of time.

Usage

G04 [P<time>]

Parameters

  • P[time]: delay time in miliseconds.

Example

G01 X0 Y0 Z-350
G4 P500          ;delay 500ms
G01 X100

G05 - Bézier cubic spline

Descriptions

G5 creates a cubic B-spline in the XY plane with the X and Y axes only. P and Q parameters are required. I and J are required for the first G5 command in a series. For subsequent G5 commands, either both I and J must be specified, or neither.

Usage

G5 [F<rate>] I<pos> J<pos> P<pos> Q<pos> X<pos> Y<pos>

Parameters

ParameterDescription
F[rate](mm/s) The maximum feedrate of the move between the start and end point. This value applies to all subsequent moves.
I[offset](mm) Offset from the X start point to first control point.
J[offset](mm) Offset from the Y start point to first control point.
P[offset](mm) Offset from the X end point to second control point.
Q[offset](mm) Offset from the Y end point to the second control point.
X[pos](mm) A destination coordinate on the X axis.
Y[pos](mm) A destination coordinate on the Y axis.

Example

;program a curvy “N” shape
G0 X0 Y0
G5 I0 J3 P0 Q-3 X1 Y1

G06 - Theta angle control

Descriptions

Directly control movement angle without endpoint coordinates.

Usage

G06 [X<angle>] [Y<angle>] [Z<angle>]

Parameters

ParameterDescription
X[angle](degree) The value of the Theta 1 angle.
Y[angle](degree) The value of the Theta 2 angle.
Z[angle](degree) The value of the Theta 3 angle.

Example

G6 X0 Y0 Z0      ;set theta 1, theta 2, theta 3 angle at 0 deg

G28 - Homing

Descriptions

Auto-home all axes, moving them towards their endstops until triggered.

Usage

G28

G90 - Absolute Movement Mode

Descriptions

In absolute mode, all coordinates given in G-code are interpreted as positions in the logical coordinate space.

Usage

G90

Note

Absolute positioning is the default.


G91 - Relative Movement Mode

Descriptions

Set relative position mode. In this mode, all coordinates are interpreted as relative to the last position.

Usage

G91

Example

G91              ; Set all axes to relative

G93 - Get Current Position

Descriptions

Get current position of end effector.

Usage

G93

Feedback

  • <xpos>, <ypos>, <zpos>
    • <xpos> : Current X position.
    • <ypos> : Current Y position.
    • <zpos> : Current Z position.

Example

G93              ; get current pos

return:
31, 43, -270

M03 - Vacuum On / Gripper Close

Descriptions

M03 is used to turn on the vacuum pump or close the gripper.

Usage

M03

Example

G01 X0 Y0 Z-350
M03                   ;turn on Vacuum pump
G01 Z-300

M04 - Turn on digital output pins

Descriptions

M04 is used to turn on and set PWM value for digital output pin (D0 - D3).

Usage

M04 [D<pin>] [P<value>]

Parameters

ParameterDescription
D[pin](0 ~ 3) The index of output pin
P[value](0 - 255) The value of the pwm

Example

M04 D1 P128 ;set pin D1 pwm at 50% 

M05 - Vacuum Off / Gripper Open

Descriptions

M05 is used to turn off the vacuum pump or close the gripper.

Usage

M05  ;turn off vacuum

M06 - Turn off digital output pins

Descriptions

M06 is used to turn off digital output pin (D0 - D3).

Usage

M06 [D<pin>]

Parameters

ParameterDescription
D[pin](0 ~ 3) The index of output pin

Example

M06 D1 ;turn off pin D1

M07 - Read Input Signals

Descriptions

M07 is used to read the input signal from the input pins.

Usage

M07 [I<pin>] [A<pin>]

Parameters

ParameterDescription
I[pin](0 ~ 3) The index of digital input pin
A[pin](0 ~ 1) The index of analog input pin

Feedback

  • I[pin] V[value]:

    • I[pin] : The index of digital input pin
    • V[value] : {0,1} The value of the digital input signal
  • A[pin] V[value]:

    • A[pin] : The index of analog input pin
    • V[value] : [0 ~ 4095] The value of the analog input signal

Example

M07 I0 I3              ;read digital pin I0 and I3
>>> I0 V1
>>> I3 V0
M07 A1                 ;read analog pin A1
>>> A1 V3946

M08 - Read Input Signals Automatically

Descriptions

M08 is used to read the input signal from the input pins automatically.

Usage

M08 [I<pin>]
M08 [A<pin>] [P<time>]

Parameters

ParameterDescription
I[pin](0 ~ 3) The index of digital input pin
A[pin](0 ~ 1) The index of analog input pin
P[time](ms) The time to read the analog input signal

Feedback

  • I[pin] V[value]:

    • I[pin] : The index of digital input pin
    • V[value] : {0,1} The value of the digital input signal
  • A[pin] V[value]:

    • A[pin] : The index of analog input pin
    • V[value] : [0 ~ 4095] The value of the analog input signal

Example

M08 I0   ;read digital pin I0 automatically
M08 A1 P1000  ;read analog pin A1 every 1000ms

M09 - Disable Automatic Reading Analog Input Signal

Descriptions

M09 is used to disable automatic reading the analog input signal.

Usage

M09 [A<pin>]

Parameters

ParameterDescription
A[pin](0 ~ 1) The index of analog input pin

Example

M09 A1  ;disable automatic reading analog pin A1

M50 - Enable RJ45

Descriptions

This command can be used to enable or disable RJ45 port.

Usage

M50 A<x>

Parameter

  • A[x]
    • x = 1 : enable RJ45
    • x = 0 : disable RJ45

Example

M50 A1           ; enable RJ45

M51 - Set Ethernet Port

Descriptions

Set ethernet port number

Usage

M51 B<x>

Parameter

ParameterDescription
B[x]port number

Example

M51 B8080         ; set ethernet port

M52 - Set MAC Device

Descriptions

Set MAC address of the robot

Usage

Address form: A:B:C:D:E:F

M52 A<x> B<y> C<z> D<t> E<u> F<v>

Parameter

ParameterDescription
A[x]number
B[y]number
C[z]number
D[t]number
E[u]number
F[v]number

Example

M52 A12 B23 C34 D45 E56 F67

>>> MAC add: 12-23-34-45-56-67 

M53 - Set Ethernet IP

Descriptions

Set ethernet IP of robot

Usage

M53 A<x> B<y> C<z> D<t>

Parameter

ParameterDescription
A[x]number
B[y]number
C[z]number
D[t]number

Example

M53 A192 B168 C1 D1

>>> IP: 192.168.1.1

M54 - Set Ethernet DNS

Descriptions

Set ethernet DNS address

Usage

M54 A<x> B<y> C<z> D<t>

Parameter

ParameterDescription
A[x]number
B[y]number
C[z]number
D[t]number

Example

M53 A192 B168 C1 D3

>>> DNS IP: 192.168.1.3

M55 - Set Ethernet Gateway

Descriptions

Set ethernet gateway address

Usage

M55 A<x> B<y> C<z> D<t>

Parameter

ParameterDescription
A[x]number
B[y]number
C[z]number
D[t]number

Example

; set ethernet gateway address 192.168.3.1
M55 A192 B168 C3 D1

M56 - Set Ethernet Subnet

Descriptions

Set ethernet gateway address

Usage

M56 A<x> B<y> C<z> D<t>

Parameter

ParameterDescription
A[x]number
B[y]number
C[z]number
D[t]number

Example

; set ethernet subnet address 192.168.3.1
M56 A192 B168 C3 D1

M57 - Get Robot IP

Descriptions

Get the IP of Delta X 2 Plus Robot

Usage

M57

Example

M57

>>> 192.168.2.2

M84 - Disable Steppers

Descriptions

This command can be used to disable steppers.

Usage

M84

M203 - Set Feedrate

Descriptions

Set movement feedrate.

Usage

M203 S<value>

Parameters

ParameterDescription
S[value](mm/s) max feedrate.

Example

M203 S500  ;Set max feedrate

M204 - Set Acceleration

Descriptions

Set movement acceleration.

Usage

M204 A<value>

Parameters

ParameterDescription
A[value](mm/s2) end effector acceleration.

Example

M204 A5000  ;Set movement acceleration.

M205 - Set Begin/End Velocity

Descriptions

Set segment begin/end velocity.

Usage

M205 S<value>

Parameters

ParameterDescription
S[value](mm/s2) end effector begin/end velocity.

Example

M205 S40  ;Set begin speed at 40 mm/s

M206 - Set Axis Offset

Descriptions

Set home offset for one or all axis.

Usage

M206 [X<value>] [Y<value>] [Z<value>]

Parameters

ParameterDescription
X[value](mm) X offset value.
Y[value](mm) Y offset value.
Z[value](mm) Z offset value.

Example

M206 X20 Y-10 Z30  ;Set home offsets

M207 - Set Z Safe

Descriptions

Set the lowest Z level that the robot cannot exceed.

Usage

M207 [Z<value>]

Parameters

ParameterDescription
Z[value](mm) Z safe value.

Example

M207 Z-870  ;Set Z safe value

M210 - Set Theta Movement Parameter

Descriptions

Config theta movement para like speed, accel, jerk, start velocity and end velocity.

Usage

M210 [F<value>] [A<value>] [J<value>] [S<value>] [E<value>]

Parameters

ParameterDescription
F[value](unit/s) speed.
A[value](unit/s^2) accel.
J[value](unit/s^3) jerk.
S[value](unit/s) start velocity.
E[value](unit/s) end velocity.

Example

M210 F2000 A4000 J800000 S30 E30  ;set all theta movement para

M360 - Select End Effector

Descriptions

Select the end effector for the robot. You can change the end effector to one of these : Vacuum, gripper, pen, laser, printer or use your custom end effector.

Usage

M360 E<value>

Parameters

  • E[value]
    • 0-Vacuum (default).
    • 1-Gripper
    • 2-Pen
    • 3-Laser
    • 4-Printer
    • 5-Custom

Example

M360 E2  ;select the end effector is Pen

M361 - Set minimum moving distance

Descriptions

Set the length of minimum moving distance.

Usage

M361 P<len>

Parameters

ParameterDescription
P[len](mm) Length in mm.

Example

M361 P0.1    ;set minium moving distance = 0.1mm

M500 - Save Settings

Descriptions

Save all configurable settings to EEPROM.

Usage

M500

Example

M500    ;Save settings

M501 - Restore Settings

Descriptions

Load all saved settings from EEPROM.

Usage

M501

Example

M501    ;Restore all settings.

M502 - Reset Settings

Descriptions

Reset all configurable settings to their factory defaults.

Usage

M502

Example

M502    ;reset

Contact Us

Found something that could be clearer?Suggest an edit

What are you working on?

Try a command like G28, a model, or a topic like wiring.