GCODES FOR DESKTOP CONVEYOR¶
Communication and Responses¶
- Use 115200 baud for the serial connection, or a TCP connection to the configured Ethernet IP address and port.
- Send one command per line, terminated by LF (
\n). CRLF is also accepted. Command names and parameter letters are case-sensitive. - Separate parameters with spaces. Angle brackets in usage descriptions are placeholders; do not send the brackets.
M315,M317,M318, andM319process only the first option on a line. Send separate commands to change several settings.- Most setting commands return
Ok. Queries return their data without a trailingOk.M312returnsOkwhen the position move finishes, rather than immediately. - Wait for the expected response before sending the next command. The firmware does not queue position moves.
- Serial lines are limited to 128 printable characters. An oversized line is discarded and returns
Unknown:UART line too long!.
Examples show commands and responses separately. Values in response examples are illustrative unless identified as the firmware version or date.
Detect Desktop Conveyor COM Port¶
Send IsXConveyor to identify the conveyor controller.
Usage¶
IsXConveyor
Response¶
YesXConveyor
The same firmware also recognizes IsXEncoder and replies with YesXEncoder.
Firmware Information¶
Usage¶
FirmwareVersion
Date
Responses for this firmware¶
FirmwareVersion:1.1.3
FirmwareDate:27/10/2026
Device Address¶
Read the stored device address with Address, or set it with Address:<value>. The address is a 16-bit unsigned value (0?65535) and is saved to nonvolatile memory. It is a device identifier, not the Ethernet IP address or TCP port; commands do not need an address prefix.
Set an address¶
Address:1
Response: Ok.
Read the address¶
Address
Example response:
Address:1
M310 - Set Motion Mode¶
Select how the motor pins are used.
Usage¶
M310 <mode>
| Mode | Function |
|---|---|
0 |
Output-pin mode. Use M314 to set the motor pin levels directly. |
1 |
Position mode. Use M312 to move and M313 to set the move speed. |
2 |
Velocity mode. Use M311 to set the speed and direction. |
3 |
Potentiometer mode. The onboard potentiometer sets speed and direction. This is not a button-control mode. |
Changing to a different mode stops the current motion and resets the motor’s position to zero. Sending the mode that is already active leaves the position unchanged. The selected mode is saved to nonvolatile memory.
Example¶
M310 1
Response: Ok.
M311 - Set Speed In Velocity Mode¶
Set the target speed in mm/s. Positive and negative values select opposite directions; 0 requests a stop. Speed changes and direction reversals use the configured acceleration.
Use M310 2 for serial/TCP velocity control. In mode 3, the firmware also accepts M311, but the next potentiometer update replaces the requested speed. In other modes, the speed request is ignored even though the command returns Ok.
Usage¶
M311 <speed>
Example¶
M311 200
Response: Ok. This acknowledges the command; it does not mean the target speed has already been reached.
M312 - Set Position¶
Move to an absolute motor position in mm, measured from the origin established at startup or the last change of motion mode. The target is not a relative distance from the current position.
The conveyor must be in position mode (M310 1) and have no position move in progress. Set the move speed with M313 before starting. A request made in another mode or during an active position move is ignored without a completion response.
Usage¶
M312 <position>
Example¶
M312 123
Response: Ok when the move finishes. If the target is already the current position, Ok is returned immediately.
Sending M310 1 again while already in position mode does not reset the origin.
M313 - Set Speed In Position Move¶
Set the speed, in mm/s, for subsequent M312 moves. The firmware uses the absolute value of the supplied speed; direction comes from the target position.
Usage¶
M313 <speed>
Example¶
M313 300
Response: Ok. This speed setting is not saved to nonvolatile memory.
M314 - Set Motor Pins Level¶
An alternate function of the motor pins, available only in output-pin mode (M310 0). This command is not used for normal conveyor motion.
Usage¶
M314 P<pin> V<level>
| Parameter | Values |
|---|---|
P<pin> |
0: pulse pin (PUL); 1: direction pin (DIR); 2: enable pin (EN). |
V<level> |
0: LOW; 1: HIGH. |
Keep the parameter order P then V. Response: Ok. In other motion modes, the pins are not changed even though Ok is returned.
M315 - Config Conveyor Parameters¶
Read the conveyor configuration or change one setting per command. Additional options on the same line are ignored.
Usage¶
M315
M315 S<pulses_per_mm>
M315 R<reverse>
M315 E<enable>
M315 P
M315 A<acceleration>
| Option | Function |
|---|---|
| No option | Read mode, motor pulses/mm, and direction reversal. |
S<value> |
Set motor pulses/mm to match the motor and transmission. Use a positive calibrated value. |
R<value> |
0: normal direction; 1: reverse direction. |
E<value> |
Store the run-with-encoder flag (0 or 1). In firmware 1.1.3 this flag is not used by the motion-control loop; it does not enable closed-loop positioning. |
P |
Stop an active position move immediately and update the estimated motor position from the pulses sent so far. It does not take a target position. |
A<value> |
Set acceleration in mm/s?. The firmware uses the absolute value. |
S, R, E, and A are saved to nonvolatile memory. Setting commands return Ok. The B parameter from X Conveyor is not implemented here.
Example: change settings separately¶
M315 S31.83
M315 R0
M315 A5000
The numbers above are examples, not factory calibration values.
Example response to M315¶
M:1 S:31.83 R:0
The query returns only M, S, and R; it does not report acceleration or the encoder flag.
After stopping a position move
Use M315 P only during an active position move. Firmware 1.1.3 leaves the move counter set after this stop, so change to another mode and back before issuing a new M312. Changing mode resets the motor position origin.
M316 - Set Encoder Mode¶
Select the encoder reporting mode. Changing the setting clears the encoder position counters and saves the mode to nonvolatile memory.
Usage¶
M316 <mode>
| Mode | Function |
|---|---|
0 |
Absolute position since the last encoder reset. |
1 |
Relative position change since the previous position report. |
2 |
Use encoder channels A and B as input pins with M319, instead of decoding encoder pulses. |
Button mode (3) is not implemented.
Example¶
M316 1
Response: Ok.
M317 - Get Position from Encoder¶
Read the position once, configure periodic position reports, or reset the encoder position. Use one option per command.
Usage¶
M317
M317 T<period_ms>
M317 R
| Option | Function |
|---|---|
| No option | Return one position report. |
T<value> |
Set the report period in milliseconds. Values from 50 to 65535 enable reporting; values below 50, including 0, stop it. |
R |
Reset the encoder position to zero. This does not reset the motor position used by M312. |
Position values use the absolute or relative mode selected by M316 and have two decimal places.
Query¶
M317
Example response:
P0:5.32
Enable periodic reports¶
M317 T500
The command returns Ok, followed by P0:<position> reports every 500 ms. Send M317 T0 to stop reporting.
Reset¶
M317 R
Response: Ok.
M318 - Set Encoder Parameters¶
Read the encoder configuration or change one setting per command. Additional options on the same line are ignored.
Usage¶
M318
M318 S<pulses_per_mm>
M318 R<reverse>
M318 C<scale>
| Option | Function |
|---|---|
| No option | Read encoder mode, scale, pulses/mm, reversal, and report period. |
S<value> |
Set the calibrated pulses/mm for the selected scale. Use a positive value. |
R<value> |
0: normal direction; 1: reverse direction. |
C<value> |
Select pulse-counting scale: 1, 2, or 4. |
Each valid setting clears the encoder position counters and saves the configuration. Changing C does not automatically adjust S; set both in separate commands. Calibration is loaded from nonvolatile memory, so this reference does not assume a fixed factory pulses/mm value.
Example¶
M318 C2
M318 S10.24
M318 R1
Each setting returns Ok. The pulses/mm value above is an example calibration for scale 2.
Example response to M318¶
M:1 C:2 S:10.24 R:1 T:500
M319 - Read Encoder Pin¶
Read channels A/B as digital inputs, or report changes to their states. Select input-pin mode with M316 2 first; these functions replace normal encoder pulse decoding.
Usage¶
M319 V<pin>
M319 T<pin>
M319 S<pin>
| Option | Function |
|---|---|
V<pin> |
Read the current input state. |
T<pin> |
Enable reports when the input state changes. |
S<pin> |
Disable reports when the input state changes. |
Pin 0 is encoder channel A; pin 1 is channel B. Send one option per command. T and S return Ok; V returns the pin state without a trailing Ok.
Example¶
M319 V1
Example response:
I1 V1
Reports use I0 V<state> or I1 V<state>, where state is 0 or 1.
M389 - Enable Ethernet¶
Set the Ethernet startup-enable flag. M389 1 also initializes Ethernet immediately with the current configuration.
Usage¶
M389 <enable>
1: set the enable flag and initialize Ethernet.0: clear the enable flag. In firmware 1.1.3, this does not close an already running Ethernet server or client connection.
The flag is saved with M396. That command also initializes Ethernet, even when the flag is 0; the disabled startup state takes effect after restarting the controller.
Response: Ok. Ethernet initialization also sends status messages to the serial connection.
M390 - Set Ethernet Port¶
Set the TCP server port in the current configuration. Save and apply the setting with M396.
Usage¶
M390 <port>
Example¶
M390 8844
Response: Ok. The source defines 8844 as the initial port, but startup loads the stored configuration. Use M397 to check the configured port.
M391 - Set Ethernet IP Address¶
Set the configured IPv4 address using four decimal octets. 0 0 0 0 selects DHCP when Ethernet is next initialized. Save and apply with M396.
Usage¶
M391 <octet1> <octet2> <octet3> <octet4>
Static-IP example¶
M391 192 168 0 2
DHCP¶
M391 0 0 0 0
Each command returns Ok.
M392 - Set Ethernet DNS Address¶
Set the configured DNS address using four decimal octets. Save and apply with M396.
Usage¶
M392 <octet1> <octet2> <octet3> <octet4>
Example¶
M392 192 168 0 1
Response: Ok.
M393 - Set Ethernet Gateway Address¶
Set the configured gateway using four decimal octets. Save and apply with M396.
Usage¶
M393 <octet1> <octet2> <octet3> <octet4>
Example¶
M393 192 168 0 1
Response: Ok.
M394 - Set Ethernet Subnet Address¶
Set the configured subnet mask using four decimal octets. Save and apply with M396.
Usage¶
M394 <octet1> <octet2> <octet3> <octet4>
Example¶
M394 255 255 255 0
Response: Ok.
M395 - Set Ethernet MAC Address¶
Set the MAC address using six decimal byte values from 0 to 255, separated by spaces. Convert a hexadecimal MAC address to decimal before sending it. Save and apply with M396.
Usage¶
M395 <byte1> <byte2> <byte3> <byte4> <byte5> <byte6>
Example¶
M395 18 52 86 120 171 5
This represents 12:34:56:78:AB:05. Response: Ok.
M396 - Save and Init Ethernet Port¶
Save the current Ethernet settings and enable flag to nonvolatile memory, then initialize the Ethernet server with those settings.
Usage¶
M396
Configure network settings through the serial connection, since applying a new configuration can interrupt the TCP connection. M396 initializes Ethernet regardless of the enable flag; set M389 1 before saving if Ethernet should start automatically after a restart.
Response: Ok. Initialization status is also printed on the serial connection.
M397 - Get Ethernet Port Parameters¶
Read the configured values held by the firmware. These may include changes that have not yet been saved or applied.
Usage¶
M397
Example response¶
E_port:8844
E_ip:192.168.0.2
E_dns:192.168.0.1
E_gateway:192.168.0.1
E_subnet:255.255.255.0
E_mac:18.52.86.120.171.5
The MAC address is reported as decimal bytes separated by dots. There is no trailing Ok.
M398 - Get Ethernet Local Port Parameters¶
Read the network stack’s active IP, DNS, gateway, and subnet. The reported port and MAC fields come from the firmware’s configured values. Use this command after Ethernet initialization to check the assigned IP address, especially when using DHCP.
Usage¶
M398
The response uses the same fields as M397, without a trailing Ok. With DHCP, the configured IP in M397 can be 0.0.0.0 while M398 shows the assigned IP address.
The text command IP returns the same network information. When sent through TCP, IP also echoes a line containing IP before the fields; the serial response has no echo line.
Contact Us¶