Desktop Conveyor — G-code reference

Commands, parameters, and practical examples for Desktop Conveyor.

On this page Communication and Responses Detect Desktop Conveyor COM Port Firmware Information Device Address M310 - Set Motion Mode M311 - Set Speed In Velocity Mode M312 - Set Position M313 - Set Speed In Position Move M314 - Set Motor Pins Level M315 - Config Conveyor Parameters M316 - Set Encoder Mode M317 - Get Position from Encoder M318 - Set Encoder Parameters M319 - Read Encoder Pin M389 - Enable Ethernet M390 - Set Ethernet Port M391 - Set Ethernet IP Address M392 - Set Ethernet DNS Address M393 - Set Ethernet Gateway Address M394 - Set Ethernet Subnet Address M395 - Set Ethernet MAC Address M396 - Save and Init Ethernet Port M397 - Get Ethernet Port Parameters M398 - Get Ethernet Local Port Parameters Contact Us
Command index 20 commands

GCODES FOR DESKTOP CONVEYOR

Communication and Responses

  • Use 115200 baud for the serial connection, or a TCP connection to the configured Ethernet IP address and port.
  • Send one command per line, terminated by LF (\n). CRLF is also accepted. Command names and parameter letters are case-sensitive.
  • Separate parameters with spaces. Angle brackets in usage descriptions are placeholders; do not send the brackets.
  • M315, M317, M318, and M319 process only the first option on a line. Send separate commands to change several settings.
  • Most setting commands return Ok. Queries return their data without a trailing Ok. M312 returns Ok when the position move finishes, rather than immediately.
  • Wait for the expected response before sending the next command. The firmware does not queue position moves.
  • Serial lines are limited to 128 printable characters. An oversized line is discarded and returns Unknown:UART line too long!.

Examples show commands and responses separately. Values in response examples are illustrative unless identified as the firmware version or date.

Detect Desktop Conveyor COM Port

Send IsXConveyor to identify the conveyor controller.

Usage

IsXConveyor

Response

YesXConveyor

The same firmware also recognizes IsXEncoder and replies with YesXEncoder.

Firmware Information

Usage

FirmwareVersion
Date

Responses for this firmware

FirmwareVersion:1.1.3
FirmwareDate:27/10/2026

Device Address

Read the stored device address with Address, or set it with Address:<value>. The address is a 16-bit unsigned value (0?65535) and is saved to nonvolatile memory. It is a device identifier, not the Ethernet IP address or TCP port; commands do not need an address prefix.

Set an address

Address:1

Response: Ok.

Read the address

Address

Example response:

Address:1

M310 - Set Motion Mode

Select how the motor pins are used.

Usage

M310 <mode>
Mode Function
0 Output-pin mode. Use M314 to set the motor pin levels directly.
1 Position mode. Use M312 to move and M313 to set the move speed.
2 Velocity mode. Use M311 to set the speed and direction.
3 Potentiometer mode. The onboard potentiometer sets speed and direction. This is not a button-control mode.

Changing to a different mode stops the current motion and resets the motor’s position to zero. Sending the mode that is already active leaves the position unchanged. The selected mode is saved to nonvolatile memory.

Example

M310 1

Response: Ok.


M311 - Set Speed In Velocity Mode

Set the target speed in mm/s. Positive and negative values select opposite directions; 0 requests a stop. Speed changes and direction reversals use the configured acceleration.

Use M310 2 for serial/TCP velocity control. In mode 3, the firmware also accepts M311, but the next potentiometer update replaces the requested speed. In other modes, the speed request is ignored even though the command returns Ok.

Usage

M311 <speed>

Example

M311 200

Response: Ok. This acknowledges the command; it does not mean the target speed has already been reached.


M312 - Set Position

Move to an absolute motor position in mm, measured from the origin established at startup or the last change of motion mode. The target is not a relative distance from the current position.

The conveyor must be in position mode (M310 1) and have no position move in progress. Set the move speed with M313 before starting. A request made in another mode or during an active position move is ignored without a completion response.

Usage

M312 <position>

Example

M312 123

Response: Ok when the move finishes. If the target is already the current position, Ok is returned immediately.

Sending M310 1 again while already in position mode does not reset the origin.


M313 - Set Speed In Position Move

Set the speed, in mm/s, for subsequent M312 moves. The firmware uses the absolute value of the supplied speed; direction comes from the target position.

Usage

M313 <speed>

Example

M313 300

Response: Ok. This speed setting is not saved to nonvolatile memory.


M314 - Set Motor Pins Level

An alternate function of the motor pins, available only in output-pin mode (M310 0). This command is not used for normal conveyor motion.

Usage

M314 P<pin> V<level>
Parameter Values
P<pin> 0: pulse pin (PUL); 1: direction pin (DIR); 2: enable pin (EN).
V<level> 0: LOW; 1: HIGH.

Keep the parameter order P then V. Response: Ok. In other motion modes, the pins are not changed even though Ok is returned.


M315 - Config Conveyor Parameters

Read the conveyor configuration or change one setting per command. Additional options on the same line are ignored.

Usage

M315
M315 S<pulses_per_mm>
M315 R<reverse>
M315 E<enable>
M315 P
M315 A<acceleration>
Option Function
No option Read mode, motor pulses/mm, and direction reversal.
S<value> Set motor pulses/mm to match the motor and transmission. Use a positive calibrated value.
R<value> 0: normal direction; 1: reverse direction.
E<value> Store the run-with-encoder flag (0 or 1). In firmware 1.1.3 this flag is not used by the motion-control loop; it does not enable closed-loop positioning.
P Stop an active position move immediately and update the estimated motor position from the pulses sent so far. It does not take a target position.
A<value> Set acceleration in mm/s?. The firmware uses the absolute value.

S, R, E, and A are saved to nonvolatile memory. Setting commands return Ok. The B parameter from X Conveyor is not implemented here.

Example: change settings separately

M315 S31.83
M315 R0
M315 A5000

The numbers above are examples, not factory calibration values.

Example response to M315

M:1 S:31.83 R:0

The query returns only M, S, and R; it does not report acceleration or the encoder flag.

After stopping a position move

Use M315 P only during an active position move. Firmware 1.1.3 leaves the move counter set after this stop, so change to another mode and back before issuing a new M312. Changing mode resets the motor position origin.


M316 - Set Encoder Mode

Select the encoder reporting mode. Changing the setting clears the encoder position counters and saves the mode to nonvolatile memory.

Usage

M316 <mode>
Mode Function
0 Absolute position since the last encoder reset.
1 Relative position change since the previous position report.
2 Use encoder channels A and B as input pins with M319, instead of decoding encoder pulses.

Button mode (3) is not implemented.

Example

M316 1

Response: Ok.


M317 - Get Position from Encoder

Read the position once, configure periodic position reports, or reset the encoder position. Use one option per command.

Usage

M317
M317 T<period_ms>
M317 R
Option Function
No option Return one position report.
T<value> Set the report period in milliseconds. Values from 50 to 65535 enable reporting; values below 50, including 0, stop it.
R Reset the encoder position to zero. This does not reset the motor position used by M312.

Position values use the absolute or relative mode selected by M316 and have two decimal places.

Query

M317

Example response:

P0:5.32

Enable periodic reports

M317 T500

The command returns Ok, followed by P0:<position> reports every 500 ms. Send M317 T0 to stop reporting.

Reset

M317 R

Response: Ok.


M318 - Set Encoder Parameters

Read the encoder configuration or change one setting per command. Additional options on the same line are ignored.

Usage

M318
M318 S<pulses_per_mm>
M318 R<reverse>
M318 C<scale>
Option Function
No option Read encoder mode, scale, pulses/mm, reversal, and report period.
S<value> Set the calibrated pulses/mm for the selected scale. Use a positive value.
R<value> 0: normal direction; 1: reverse direction.
C<value> Select pulse-counting scale: 1, 2, or 4.

Each valid setting clears the encoder position counters and saves the configuration. Changing C does not automatically adjust S; set both in separate commands. Calibration is loaded from nonvolatile memory, so this reference does not assume a fixed factory pulses/mm value.

Example

M318 C2
M318 S10.24
M318 R1

Each setting returns Ok. The pulses/mm value above is an example calibration for scale 2.

Example response to M318

M:1 C:2 S:10.24 R:1 T:500

M319 - Read Encoder Pin

Read channels A/B as digital inputs, or report changes to their states. Select input-pin mode with M316 2 first; these functions replace normal encoder pulse decoding.

Usage

M319 V<pin>
M319 T<pin>
M319 S<pin>
Option Function
V<pin> Read the current input state.
T<pin> Enable reports when the input state changes.
S<pin> Disable reports when the input state changes.

Pin 0 is encoder channel A; pin 1 is channel B. Send one option per command. T and S return Ok; V returns the pin state without a trailing Ok.

Example

M319 V1

Example response:

I1 V1

Reports use I0 V<state> or I1 V<state>, where state is 0 or 1.


M389 - Enable Ethernet

Set the Ethernet startup-enable flag. M389 1 also initializes Ethernet immediately with the current configuration.

Usage

M389 <enable>
  • 1: set the enable flag and initialize Ethernet.
  • 0: clear the enable flag. In firmware 1.1.3, this does not close an already running Ethernet server or client connection.

The flag is saved with M396. That command also initializes Ethernet, even when the flag is 0; the disabled startup state takes effect after restarting the controller.

Response: Ok. Ethernet initialization also sends status messages to the serial connection.


M390 - Set Ethernet Port

Set the TCP server port in the current configuration. Save and apply the setting with M396.

Usage

M390 <port>

Example

M390 8844

Response: Ok. The source defines 8844 as the initial port, but startup loads the stored configuration. Use M397 to check the configured port.


M391 - Set Ethernet IP Address

Set the configured IPv4 address using four decimal octets. 0 0 0 0 selects DHCP when Ethernet is next initialized. Save and apply with M396.

Usage

M391 <octet1> <octet2> <octet3> <octet4>

Static-IP example

M391 192 168 0 2

DHCP

M391 0 0 0 0

Each command returns Ok.


M392 - Set Ethernet DNS Address

Set the configured DNS address using four decimal octets. Save and apply with M396.

Usage

M392 <octet1> <octet2> <octet3> <octet4>

Example

M392 192 168 0 1

Response: Ok.


M393 - Set Ethernet Gateway Address

Set the configured gateway using four decimal octets. Save and apply with M396.

Usage

M393 <octet1> <octet2> <octet3> <octet4>

Example

M393 192 168 0 1

Response: Ok.


M394 - Set Ethernet Subnet Address

Set the configured subnet mask using four decimal octets. Save and apply with M396.

Usage

M394 <octet1> <octet2> <octet3> <octet4>

Example

M394 255 255 255 0

Response: Ok.


M395 - Set Ethernet MAC Address

Set the MAC address using six decimal byte values from 0 to 255, separated by spaces. Convert a hexadecimal MAC address to decimal before sending it. Save and apply with M396.

Usage

M395 <byte1> <byte2> <byte3> <byte4> <byte5> <byte6>

Example

M395 18 52 86 120 171 5

This represents 12:34:56:78:AB:05. Response: Ok.


M396 - Save and Init Ethernet Port

Save the current Ethernet settings and enable flag to nonvolatile memory, then initialize the Ethernet server with those settings.

Usage

M396

Configure network settings through the serial connection, since applying a new configuration can interrupt the TCP connection. M396 initializes Ethernet regardless of the enable flag; set M389 1 before saving if Ethernet should start automatically after a restart.

Response: Ok. Initialization status is also printed on the serial connection.


M397 - Get Ethernet Port Parameters

Read the configured values held by the firmware. These may include changes that have not yet been saved or applied.

Usage

M397

Example response

E_port:8844
E_ip:192.168.0.2
E_dns:192.168.0.1
E_gateway:192.168.0.1
E_subnet:255.255.255.0
E_mac:18.52.86.120.171.5

The MAC address is reported as decimal bytes separated by dots. There is no trailing Ok.


M398 - Get Ethernet Local Port Parameters

Read the network stack’s active IP, DNS, gateway, and subnet. The reported port and MAC fields come from the firmware’s configured values. Use this command after Ethernet initialization to check the assigned IP address, especially when using DHCP.

Usage

M398

The response uses the same fields as M397, without a trailing Ok. With DHCP, the configured IP in M397 can be 0.0.0.0 while M398 shows the assigned IP address.

The text command IP returns the same network information. When sent through TCP, IP also echoes a line containing IP before the fields; the serial response has no echo line.


Contact Us

Found something that could be clearer?Suggest an edit

What are you working on?

Try a command like G28, a model, or a topic like wiring.