Command index 4 commands

GCODES FOR SHORT CONVEYOR

Communication and Responses

  • Connect at 115200 baud, with 8 data bits, no parity, and 1 stop bit.
  • Send one command per line, ending with a newline (\n). CRLF is also accepted for the numeric commands below.
  • Use uppercase command names, starting at the beginning of the line, followed by a space and a numeric value: M311 50.
  • Values are positional: use M311 50, not M311 S50. These commands are setters, not queries; always provide a value. Missing or nonnumeric values can be parsed as zero.
  • The controller prints Begin: at startup and starts in potentiometer mode. The knob can therefore start the belt after power-on or reset.
  • M310, M311, and M313 reply with Ok immediately. A nonzero M312 normally replies with Ok when its move completes.
  • Settings are held in RAM and return to startup defaults after a reset. There is no save-to-memory command.

This firmware implements M310, M311, M312, and M313 only. It does not implement IsXConveyor, encoder feedback, general-purpose input/output commands, or Ethernet commands. Unsupported commands do not produce an error reply.

Quick Start

Send each line separately and wait for its Ok reply before continuing.

  1. Select serial control:

    text M310 1

  2. Run continuously at 50 mm/s:

    text M311 50

  3. Stop continuous motion:

    text M311 0

For a relative position move, set the position speed with M313, then send M312 and wait for its completion reply.

M310 - Select Control Mode

Select whether the potentiometer or serial commands control the conveyor.

Usage

M310 <mode>

Parameters

Parameter Description
0 Potentiometer mode, the startup default. The knob controls speed from 0 to 200 mm/s in one direction.
1 Serial mode. Use M311 for continuous motion and M312 for relative moves.

The potentiometer is ignored in serial mode. Selecting serial mode sets the continuous speed request to zero; it does not clear an active position move.

Select M310 1 before sending serial movement commands. In potentiometer mode, those commands do not immediately drive the motor, even when a command returns Ok.

Example

M310 1

Response: Ok.

Switch modes only after a position move has completed. Returning to M310 0 lets the current knob setting control the belt again.

M311 - Set Continuous Speed

Run continuously at a signed speed, or stop continuous motion. Requires serial mode (M310 1).

Usage

M311 <speed>

Parameters

Parameter Description
<speed> Speed in mm/s. Positive and negative values select opposite directions. 0 stops continuous motion.

The firmware limits the speed magnitude to 200 mm/s. A magnitude below 0.01 mm/s is treated as zero. It changes the step timing directly, without an acceleration ramp.

Examples

Run at 50 mm/s:

M311 50

Run in the opposite direction:

M311 -50

Stop continuous motion:

M311 0

Each command replies with Ok. This acknowledges the command; it is not measured speed feedback.

M311 0 does not cancel an active M312 position move. Wait for that move to finish before using continuous-speed commands.

M312 - Move Relative Distance

Move a signed distance from the current belt position, then stop. Requires serial mode (M310 1). Set the movement speed with M313.

Usage

M312 <distance>

Parameters

Parameter Description
<distance> Relative distance in mm. Positive and negative values select opposite directions. This is not an absolute position or a homing command.

The firmware converts distance to steps using 84 steps/mm, rounded to the nearest whole step. Position is calculated from commanded motor steps; there is no encoder verification.

Direction convention

In this firmware, positive M312 moves in the opposite direction to positive M311. Negative values also have opposite direction conventions between the two commands.

Example

From a stopped conveyor in serial mode, set a position speed of 30 mm/s and wait for Ok:

M313 30

Move 100 mm and wait for the completion Ok:

M312 100

Move 100 mm in the opposite direction:

M312 -100

Completion and Sequencing

  • For a nonzero move, Ok is sent when the requested step count completes. The firmware then stops the step timer and disables the motor driver.
  • M312 0 returns Ok immediately, but does not cancel a move that is already running.
  • There is no motion queue or position-move cancellation command. Wait for completion before sending another motion, mode, or position-speed command; commands sent during a move can modify its active step count, direction, or speed.
  • Very small nonzero distances can round to zero steps and produce no completion reply. One step is approximately 0.0119 mm; use distances of at least one step for normal positioning.

M313 - Set Position Move Speed

Set the speed used by M312. The startup default is 30 mm/s. Configure this while the conveyor is stopped, before starting a position move.

Usage

M313 <speed>

Parameters

Parameter Description
<speed> Positive position-move speed in mm/s. Use a value no greater than 200 mm/s. Direction is selected by the sign of M312, not by this value.

The firmware assigns this value directly: it does not validate or clamp M313 like it does M311. Do not use zero or negative values. This setting is lost after reset.

Example

M313 40

Response: Ok.

Subsequent M312 moves use 40 mm/s. M313 does not specify a distance and does not start a move from idle.